AQUAFIRE SYSTEMS
INTUMESCENT FIRE PROTECTION COATINGS FOR TIMBER
AQUAFIRE FRC  -  AQUAFIRE HP  -  AQUAFIRE DOORKITS
APPLICATION INFORMATION   |   FIRE PERFORMANCE DATA   |   COLOUR APPLICATION DATA   |   CLEAR APPLICATION DATA   |   BUILDING REGULATION GUIDE
CLEAR APPLICATION DATA
APPLICATION RATE

BASECOAT
TOPCOAT
TOTAL DFT
150 microns
60 microns
COVERAGE
380 g/sq.m
207 g/sq.m
TOUCH DRY
1 hour
1 hour
HARD DRY
4-6 hours
4-6 hours
No. of components
Single Unit
Single Unit
Usable Life
Indefinite
Indefinite
Solids by Volume
56%
29%

Note:
Drying time for Overcoating     6 hours(min)

For the best results with Aquafire FRC we recommend the substrate should be thoroughly dry and each coat allowed to dry fully before applying further coats.


For further information


For further information contact:
AQUAFIRE SYSTEMS
TECHNICAL SERVICES DEPARTMENT
0131 440 4450