AQUAFIRE HP SYSTEM

Aquafire HP coating system is designed for application by shopfitters and contractors where a very high standard of finish is required in areas that have to comply with the fire protection reqirements of the Building Regulations.
The Aquafire HP System comprises a two-pack water based intumescent lacquer followed (when dry) by a two-pack topcoat which is available in Gloss, Semi Matt and Matt finishes.
Suitable for use on timber based products including softwoods, hardwoods and veneered or plain chipboard and medium density fibreboard (MDF).
Provides Class 1 Surface Spread of Flame (BS 476:Part 7:1987) and Class 0 Fire Propagation (BS476:Part 6:1991) requirements of the Building Regulations.

Satisfies the heavy/severe use requirement of BS 6250:Part 3:1991 for horizontal surfaces.

Holyrood Assembly

Treated with Aquafire HP
REPORT
NUMBER
TESTING
HOUSE
SUBSTRATE
MATERIAL
TEST
TYPE
TEST
RESULTS
BUILDING
REGULATION
CLASSIFICATION
TE85634 TE85639
LPC
MDF
#1
#2
PASS CLASS 1
CLASS 0
TE85635 TE85640
LPC
LIGHT OAK
#1
#2
PASS CLASS 1
CLASS 0
TE85636 TE85641
LPC
MAHOGANY
#1
#2
PASS CLASS 1
CLASS 0
TE85637 TE85642
LPC
VENEERED CHIPBOARD
#1
#2
PASS CLASS 1
CLASS 0
TE85638 TE85643
LPC
VENEERED MDF
#1
#2
PASS CLASS 1
CLASS 0
TEST TYPES: Test type #1 - Test to BS476: Part 6: 1989. Class 0. Test Type #2 - Test to BS476: Part7: 1987 Class 1